DOUT9.STATE to DOUT11.STATE

Description

This parameter allows the user to see the actual level of the output signal, when the IO is set to output mode. Parameter value is 0 if signal is low and 1 if signal is high. DIOx.INV can affect the signals driven onto the X9 connector.

This parameter can be read at any time. The value is only guaranteed to correspond to the output on the X9 connector when DRV.EMUEMODE is set to 10 and the DIOX.DIR is 0.

General Information

Type

NV parameter

Units

N/A

Range

0 to 1

Default Value

0

Data Type

U8

Start Version

M_01-05-00-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD Profinet Yes
AKD sercos® III Yes
AKD-N No
AKD-C No

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

Parameter

Fieldbus

Address

Attributes Signed?
DOUT9.STATE

Profinet

2782

Byte No
sercos® III 2 Octets
DOUT10.STATE

Profinet

2728 Byte
sercos® III 2 Octets
DOUT11.STATE

Profinet

2730 Byte
sercos® III 2 Octets
Fieldbus Parameter Instance Data Size Data Type
EtherNet/IP DOUT9.STATE 783 1 Byte Integer
DOUT10.STATE 729
DOUT11.STATE 731
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1564 DOUT9.STATE No 8 bit No M_01-06-03-000
1456 DOUT10.STATE
1460 DOUT11.STATE

Related Topics

DIO9.DIR to DIO11.DIR

DIO9.INV to DIO11.INV

DOUT9.STATEU to DOUT11.STATEU

DRV.EMUEMODE